Power Factor Correction Capacitors Cylindrical Type

。Rated Voltage Level (kV): 0.23, 0.25, 0.4, 0.45, 0.48, 0.525;
。Rated Capacity (kvar): 1~50;
。1~10kvar: Single-ended terminal;
。12.5~30kvar: Screw terminal;
。35~50kvar: Delta terminal(<400V);Screw terminal(>400V)
。Capacitance Deviation (uF): -5% to +10%;
。Loss Tangent (tanφ): <0.1% (at Un, 50Hz, 20℃);

Read More

Split-Phase Capacitors

With the development of reactive power compensation technology, for three-phase unbalanced loads, the method of separately switching capacitors for each phase can be employed to compensate for the reactive power of each phase.

This approach enhances compensation accuracy and improves energy-saving effects. To achieve this, our company has developed a parallel capacitor configuration that enables both phase-by-phase and inter-phase compensation, facilitating the selective switching of capacitors for different phases.

Read More

ANTI-Harmonic Capacitors

These capacitors possess a higher ability to withstand currents and are connected in series with reactors to suppress harmonic current amplification and prevent resonance. Additionally, this product functions as a reactive power compensator.

。Rated Voltage Levels (kV): 0.45, 0.48, 0.525.
。Rated Capacity (kvar): 15~60.
。Capacitance Deviation (μF): 0~+3%.
。Dissipation Factor (tanδ): ≤0.1% (at Un, 50Hz, 20℃).

Read More

AC-Filter Capacitors

。Rated Voltage Levels (kV): 0.33, 0.45, 0.48, 0.525, 0.80
。Rated Capacity (kVar): 15~100
。Capacitance Tolerance (μF): 0~+3%
。Loss Tangent (tanδ): ≤0.1% (at Un 50Hz 20℃)

Read More

Resonant Capacitors

。High capacity, high bit characteristics
。Fully water-cooled, semi-water-cooled
。Environmentally friendly medium
。Pressure protection
。Altitude: <2000m
。Ambient Temperature: 5℃~45℃
。Relative Humidity: ≤85%
。Capacity Deviation: ±5%
。Rated Voltage: 1-3.4kV

Read More

DZMJ DC Filter Capacitor

The role of DZMJ DC filter capacitors is to provide filtering and voltage support on the direct current (DC) side of the power supply.

。Large capacity: 300~5000μF
。High current: Maximum current reaches 2500A
。High voltage: 800~1800VDC
。Cooling method: Full water cooling or semi-water cooling
。 Non-toxic impregnating agent
。 Equipped with pressure protection relay

Read More

Protecting Absorption Capacitors

In power supplies where thyristors are used as switches, they are connected in series with resistors to form an RC absorption protection circuit. This circuit prevents voltage spikes during thyristor turn-off, thereby protecting the thyristors.

。Altitude Environment: <2000m
。Temperature Range: -25 to +40°C
。Humidity Level: <85%
。Protection Rating: IP00 for indoor installation

Read More

Pole mounted oil transformer

1 Power transformer 10kv and 35kv low-loss series
2 low loss, low noise, high reliability
3 Iron core is made of cold-rolled silicon-steel
4 Have good ability withstand short-circuit
5 The oil tank is bell type with the structure of full folding plate type,

Read More

S9 20KV oil HV transformer

power distribution transformer
1.Standards: IEC60076
2.Rated voltage:10kV
3.Low wastage,low noise
4.Easy installation

Read More

S9-M 10KV oil transformer

。Altitude: ≤1, 000m
。Highest ambient temperature: +40℃
。Highest annual average temperature: +20℃
。Highest monthly average temperature: +30℃
。Lowest temperature: -25℃

Read More

S11 20kv oil transformer

。Standard: IEC60076, GB1094-1996; JB/T10088-2004; GB/T6451-2008; EQV
。Voltage Grade: 6KV to 35KV
。 Voltage Regulation Mode: No-load tap changing or On-load tap changing
。Tapping Range: ±5%, ±2×2.5%, ±4×2.5% or others
。Frequency: 50Hz; 60Hz

Read More

S11 S11M 10KV oil high voltage transformer

。Rated Capacity (KVA): 10~2500 KVA
。Vector Group: Yyn0 or Dyn11
。Impedance Voltage (%): 4%, 4.5%
。Rated voltage: H. V: 11, 10.5, 10, 6.3, 6KV (or customized)
。L. V.: 0.4, 0.69KV (or customized)

Read More

SC(B)9 resin insulated distribution transformers

。Voltage class: 6-35KV
。Model of voltage regulation: Off-excitation or on-load tap changer
。Tapping range: 5%, 2x2.5%,
。Power Capacity: 10-4000kVA
。Frequency: 50Hz or 60HZ

Read More

Dry type resin insulated SC(B)10 distribution transformers

Altitude: ≤1, 000m
Highest ambient temperature: +40℃
Highest annual average temperature: +20℃
Highest monthly average temperature: +30℃
Lowest temperature: -25℃

Read More

SC(B)11 High Voltage Transformer

6. Phase No.: Single phase or three phase
7. Vector Group: Yyn0 or Dyn11
8. Impedance voltage: 4~8%
9. Service condition: 100% relative humidity, ambient temperature not more than 40oC or according to customers' requirements
10. Type of cooling: AN or AF

Read More

ZUW1 drawout type air circuit breakers

2.1 Temperature condition:  -5°C~40°C;the average value within 24h shall not exceed+35°C(special situation  excluded);
2.2 Altitude:≤2000m;
2.3 Pollution grade:  Grade 3;
2.4 Air conditions:

Read More

ZUW1 fixed type air circuit breakers

At mounting site, relative humidity not exceed 50% at the max temperature of +40°C, 
higher relative humidity is allowable under lower temperature,
RH could be 90% at +20°C, special measures  should be taken to occurrence of dews;
The products conform with IEC60947-1,IEC60947-2 standards.

Read More

ZW7-40.5 outdoor HV vacuum circuit breaker

? Installation way: foundation installation;
? Operating mechanism: spring operating mechanism and electromagnetic operating mechanism;
? Pole material: rubber silicone, ceramic;
? Application: outdoor 33kV substation, power plant.
? Current transformer: internal installation, external installation.

Read More

ZW8-12/C intelligent outdoor high-voltage vacuum circuit breaker

is applied for breaking, on Or off of load current in AC three-phase power system of rated 10-12kV with 50/60Hz, 
it owns functions of overload and short protection, fast breaking protection, time lapse delay and automatic reclosing ,
it can also be equipped with arrester Or disconnecting (circuit breaker and disconnecting switch combination, 
hereinafter called combination intelligent circuit breakers) according to customer' s requirement.

Read More

ZW20Z-12 outdoor high voltage vacuum circuit breaker

for a period of 12 KV, rated voltage of the three-phase ac 50 HZ outdoor power distribution system. 
It uses a vacuum arcing and SF6 gas as insulating medium, 
is ZW20-12 type vacuum circuit breaker of the improvement of products. 
Cabinet adopted the introduction of Japanese Toshiba VSP5 gas seal technology, explosion-proof, insulating structure

Read More

ZW32-12 Permanent magnetic outdoor vacuum circuit breaker

? Ambient temperature: -35°C ~ +45°C;
? Altitude: ≤1000m;
? Wind speed ≤ 35m/s;
? Earthquake intensity: ≤8 level;
? Filthy level: IV;

Read More

ZW32-24 outdoor HV vacuum circuit breaker

? Installation way: pole mounted;
? Operating mechanism: spring operating mechanism and permanent magnetic operating mechanism;
? Pole type: integrated pole;
? Application: outdoor 24kV substation, power plant.
? Operation type: manual, electric, remote control.

Read More

GN19-12 indoor high voltage disconnect switch

1. The altitude: under1000M;
2. The ambient temperature: -25°C-+40°C;
3. The relative humidity of air monthly≤90%, daily≤95%;
4. The wind pressu re:≤7000PA(with speed 34m/s);
5. Ampitude: Earthquake degree 8;

Read More

GN27-40.5 indoor high voltage disconnect switch

1. Altitude:≤1000m;
2. 2. Ambient temperature: -25°C~+40 °C;
3. Relative humidity: daily average≤95%, monthly average ≤90%;
4. Earthquake intensity:≤8 degree;
5. Applicable occasions should free from inflammables, explosives Corrosives and severe vibration

Read More
Professional Molded Case Or Vacuum Circuit Breaker and Power Capacitor manufacturer
ZHIYUE GROUP CO.LTD is a factory who mainly produce power capacitor, intelligent reactive compensation controller, vacuum circuit breaker , high and low voltage power transformer, high and low voltage reactive compensation device, harmonic solving device. It is a company which integrate research, produce, trade , service as a unit.
32+ Years
Of Experience
6800㎡
Workshop Area
300+
Technical Personnel
7*24
Quick Answer
News Center

Overview of high-voltage load switches, functions, precautions, environmental conditions, and application areas

What is high voltage disconnect switch?

Principles for the use of high-voltage isolation switches and circuit breakers

how to install high voltage power capacitor

Can't find what you're looking for?
In the past 32 years, Zhiyue Group Co., Ltd. has been helping many well-known companies and organizations to provide high-voltage power capacitors, low-voltage capacitors, vacuum contactors, vacuum circuit breakers, high-voltage load switches, high-voltage disconnect switch, high voltage transformer.
Contact Our Experts
Message
Cell Phones Telephone E-mail

Back To Top

Leave Message Here!
GET IN TOUCH NOW
×