S9-M 10KV oil transformer

Notes

。Altitude: ≤1, 000m
。Highest ambient temperature: +40℃
。Highest annual average temperature: +20℃
。Highest monthly average temperature: +30℃
。Lowest temperature: -25℃

Detailed introduction

S9-M 10KV oil transformer manufacturer

S9-M 10KV Oil Type High Voltage Transformer

Structure Characteristics:
S9-M 10kv oil immersed distribution transformers are widely used for power supply & distribution in industrial and civil occasions, to step down grid voltage (11, 10.5, 10, 6.3, 6KV) to line voltage 400, which can serve both indoors and outdoors at an ambient temperature range -25℃ to 40℃. With reasonable structure design, the transformers are qualified to withstand short-circuit and overload, and are free of maintenance and easy to repair.
The transformers have S9 and advanced S11 series, the S11 is more recommended for less loss of both load and no-load.
Product standard:  IEC60076 & GB1094 and GB/T6451

Main specification:
Rated Capacity (KVA): 10~2500 KVA
Vector Group: Yyn0 or Dyn11
Impedance Voltage (%): 4%, 4.5%
Rated voltage: H. V: 11, 10.5, 10, 6.3, 6KV (or customized)
L. V.: 0.4, 0.69KV (or customized)
Tapping range: +/- 5% or +/- 2 * 2.5%  (or customized)
Frequency: 50/60Hz
Number of phases: 3
Cooling method: ONAN
Temperature rise limits: Winding ≤ 65K, Top oil ≤ 60K
Standards: IEC60076 Power transformer, GB1094 Power transformer, GB/T6451 Technical
data & requirement of three-phase oil immersed power transformer

Ambient conditions:
Altitude: ≤1, 000m
Highest ambient temperature: +40℃
Highest annual average temperature: +20℃
Highest monthly average temperature: +30℃
Lowest temperature: -25℃
Indoor and outdoor

Type Voltage combination and tapping range(kV) Connection
symbol
No-load
Loss(kW)
Load
loss
No-load
Current
(%)
Impedance
(%)
Gross
Weight
(kg)
HV High voltage tapping rang LV
S9-M-30 6
6.3
10
10.5
11
±5%
or
±2×2.5%
0.4 Yyn0
Or
Dyn11
0.13 0.6 2.1 4 360
S9-M-50 0.17 0.87 2 440
S9-M-63 0.2 1.04 1.9 480
S9-M-80 0.25 1.25 1.8 530
S9-M-100 0.29 1.5 1.6 600
S9-M-125 0.34 1.8 1.5 680
S9-M-160 0.4 2.2 1.4 790
S9-M-200 0.48 2.6 1.3 900
S9-M-250 0.56 3.05 1.2 1080
S9-M-315 0.67 3.65 1.1 1250
S9-M-400 0.8 4.3 1 1500
S9-M-500 0.96 5.1 1 1700
S9-M-630 1.2 6.2 0.9 4.5 2180
S9-M-800 1.4 7.5 0.8 2395
S9-M-1000 1.7 10.3 0.7 2850
S9-M-1250 1.95 12 0.6 3370
S9-M-1600 2.4 14.5 0.6 4060
S9-M-2000 2.6 19.8 0.6 5160
S9-M-2500 Dyn11 3 23 0.6 6390
Message Feedback

If you have any enquiry about quotation or cooperation,please free to email us at niki@zhiyue.com or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.

News Center

Overview of high-voltage load switches, functions, precautions, environmental conditions, and application areas

What is high voltage disconnect switch?

Principles for the use of high-voltage isolation switches and circuit breakers

how to install high voltage power capacitor

Can't find what you're looking for?
In the past 32 years, Zhiyue Group Co., Ltd. has been helping many well-known companies and organizations to provide high-voltage power capacitors, low-voltage capacitors, vacuum contactors, vacuum circuit breakers, high-voltage load switches, high-voltage disconnect switch, high voltage transformer.