SC(B)9 resin insulated distribution transformers

Notes

。Voltage class: 6-35KV
。Model of voltage regulation: Off-excitation or on-load tap changer
。Tapping range: 5%, 2x2.5%,
。Power Capacity: 10-4000kVA
。Frequency: 50Hz or 60HZ

Detailed introduction

SC(B)9 resin insulated distribution transformers

SC(B)9 Dry Type High Voltage Transformer

General Description:
Dry type resin insulated SC(B)11, SC(B)10, SC(B)9 distribution transformers are widely used for power supply & distribution in industrial and civil occasions, to step down grid voltage (6-35KV) to line voltage 400V. The transformers are resin insulated, which is safe, non-pollute, flame proof and can be installed directly on the load centre, with the merits of free maintenance, easy installation, low operation cost, low loss and excellent humidity resistance.
Main application in: High-rise buildings, airports, terminals, power plants, transformer stations, residential areas or packages of various sites.

Product standard:  IEC60076 & GB/T10228, GB109411, GB4208, GB6450
 
Main Specifications:
1. Voltage class: 6-35KV
2. Model of voltage regulation: Off-excitation or on-load tap changer
3. Tapping range: 5%, 2x2.5%,
4. Power Capacity: 10-4000kVA
5. Frequency: 50Hz or 60HZ
6. Phase No.: Single phase or three phase
7. Vector Group: Yyn0 or Dyn11
8. Impedance voltage: 4~8%
9. Service condition: 100% relative humidity, ambient temperature not more than 40oC or according to customers' requirements
10. Type of cooling: AN or AF
11. Protection class: IP00, IP20, IP23
12. Insulation level: F/F
 
Ambient conditions:
Altitude: ≤1, 000m
Highest ambient temperature: +40℃
Highest annual average temperature: +20℃
Highest monthly average temperature: +30℃
Lowest temperature: -25℃

Model meaning


 
Technical Data:
SC(B)9 Dry-type Cast Resin Distribution Transformer

Model Voltage
Group
(kV)
Conne-
ction
Method
Insul-
ating
Impe-
dance
no-
load
loss
Loaded loss
(120℃)
No-
load current
Dimension Track
guage
Weight
without
shell (cm)
with
shell (cm)
without shell with shell
% Watt Watt % L*W
*H
D*A1*
A2*A3
L*W
*H
D*e*
f*g*h
kg kg
SC9
-10/10
High
voltage
11
10.5
10
6.3
6
Low
voltage
0.4
Dyn11
or
Yyn0
F/F 4 150 325 4.5 60*
45*
49
40*40
*40*40
90*
80*
85
40*47*
49*24
*18
550 130 250
SC9
-20/10
4 185 630 4 60*
45*
56
40*40
*40*40
90*
80*
85
40*54*
56*24
*18
550 170 305
SC9
-30/10
4 215 750 3.2 62*
45*
65
40*40
*40*40
105*
90*
100
40*62*
65*22
*18
550 360 480
SC9
-50/10
4 305 1055 2.8 62*
45*
75
40*40
*40*40
105*
900*
105
40*70*
75*22
*18
550 420 540
SC9
-63/10
4 370 1280 2.7 75*
50*
76
40*40
*40*45
105*
10*
115
40*71*
76*24
*19
550 530 650
SC9
-80/10
4 415 1460 2.6 75*
50*
76
40*40
*40*45
110*
100*
115
40*71*
76*25
*20
550 640 760
SC9
-100/10
4 450 1665 2.4 75*
50*
89
40*40
*40*45
115*
110*
125
40*80*
89*25
*20
550 785 905
SC9
-125/10
4 530 1955 2.2 106*
60*
102
55*55
*55*55
135*
105*
120
55*97*
102*32
*26
550 860 1160
SC9
-160/10
4 610 2250 2.2 106*
60*
106
55*55
*55*55
140*
105*
125
55*102*
106*32
*26
550 930 1230
SC9
-200/10
4 700 2675 2 106*
71*
112
66*66
*66*66
145*
110*
135
66*106*
112*32
*27
550 1150 1460
SC9
-250/10
4 810 2920 2 110*
71*
114
66*66
*66*66
150*
115*
140
66*111*
114*32
*28
550 1290 1600
SC9-
315/10
4 990 3670 1.8 115*
71*
120
66*66
*66*66
150*
120*
145
66*115*
120*33
*28
660 1440 1750
SC9-
400/10
4 1100 4220 1.8 126*
87*
129
66*66
*66*82
160*
125*
160
66*120*
129*36
*32
660 1680 2040
SC9-
500/10
4 1305 5170 1.8 129*
87*
136
82*82
*82*82
160*
130*
165
82*129*
136*37
*33
660 1840 2200
SC9-
630/10
6 1510 6220 1.6 145*
87*
142
82*82
*82*82
180*
130*
170
82*135*
142*36
*32
820 2280 2660
SC9-
630/10
6 1460 6310 1.6 150*
87*
137
82*82
*82*82
185*
130*
165
82*130*
137*35
*31
820 2485 2860
SC9-
800/10
6 1710 7360 1.6 155*
87*
157
82*82
*82*82
190*
130*
180
82*148*
157*38
*33
820 2620 3020
SC(B)9-
1000/10
6 1990 8600 1.4 160*
87*
167
82*82
*82*82
195*
130*
195
82*152*
167*37
*33
820 3150 3550
SC(B)9-
1250/10
6 2350 1026 1.4 168*
112*
177
107*
107*107
*107
205*
135*
200
107*160*
177*39
*34
1070 3740 4150
SC(B)9-
1600/10
6 2755 1242 1.4 175*
112*
186
107*
107*107
*107
210*
140*
210
107*169*
186*41
*37
1070 4320 4750
SC(B)9-
2000/10
6 3735 1530 1.2 177*
112*
187
107*
107*107
*107
215*
150*
210
107*170*
187*43
*41
1070 5450 5900
SC(B)9-
2500/10
6 4500 1818 1.2 187*
112*
195
107*
107*107
*107
220*
150*
220
107*172*
195*44
*42
1070 6310 6760
SC(B)9-
3150/10
8 5780 2370 1 195*
112*
190
107*
107*107
*107
235*
160*
225
107*175*
198*46
*44
1070 7260 7650
SC(B)9-
4000/10
8 6700 2850 1 210*
112*
205
107*
107*107
*107
240*
160*
230
107*185*
205*47
*45
1070 7985 8230
Message Feedback

If you have any enquiry about quotation or cooperation,please free to email us at niki@zhiyue.com or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.

News Center

Overview of high-voltage load switches, functions, precautions, environmental conditions, and application areas

What is high voltage disconnect switch?

Principles for the use of high-voltage isolation switches and circuit breakers

how to install high voltage power capacitor

Can't find what you're looking for?
In the past 32 years, Zhiyue Group Co., Ltd. has been helping many well-known companies and organizations to provide high-voltage power capacitors, low-voltage capacitors, vacuum contactors, vacuum circuit breakers, high-voltage load switches, high-voltage disconnect switch, high voltage transformer.
Contact Our Experts
Message
Cell Phones Telephone E-mail

Back To Top

Leave Message Here!
GET IN TOUCH NOW
×