Environmentally acceptable proprietary dielectric fluid that provides an ideal balance between low- and high-ambient temperature operation
。Voltage level: 1 ~ 24kV
。Capacity level: 100 ~ 800kvar
。Capacitance deviation: -3% ~ +5%
。Dielectric loss tangent value: ≤0.03%
Unfused capacitor units refer to capacitors that are not equipped with a fuse for protection. Fuses are often used in capacitor units to protect against overcurrent or short-circuit conditions that could lead to damage or failure of the capacitor.
。Voltage level: 1 ~ 24kV
。Capacity level: 100 ~ 800kvar
。Capacitance deviation: -3% ~ +5%
。Dielectric loss tangent value: ≤0.03%
Internally fused capacitor units are capacitors that have built-in fuse protection to prevent catastrophic failure in the event of a short circuit or overload.
。Voltage level: 6~35kV
。Capacity level: 0.1 to 0.5μF
。Capacitance deviation: -3 ~ +10%
。Dielectric loss tangent value: ≤0.03%e
。Environment temperature: -40 ~ +45℃
。Height: ≦1000m
。For bandpass filter, the deviation of actual and the rated capacitance are less than ±5%.
。For high-pass filter, the deviation of actual and the rated capacitance are less than ± 7.5%.
。Rated voltage: 6.3kV, 6.6kV, 6.6/√3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11/√3kV, please indicated in the order if you want the other special capacity.
。Rated capacity: 33~334kvar please indicated in the order if you want the other special capacity.
。Capacity tolerance: -5 ~ 15%.
。Loss angel tangential value: film & papaer medium tg θ≦0.08%,film medium tg θ≦0.05%.
Altitude: less than 1000m; Ambient Temperature: -40℃ ~ +40℃。
No violent mechanical vibration, no harmful gas and vapor, no electric, and explosive, and explosive dust in location.
Continuous operation voltage: 1.00 Un, long-term max, Over voltage: less.1 Un.
Stable over-curent (including harmonics current) less 1.3 In.
1. the frequency of system
2. rated current
3. Rated reactance rates.
4. rated capacity
5. the style of installation(horizontal/ overstow)
Capacitance Deviation (uF): -5% to +10%;
Loss Tangent (tanφ): <0.1% (at Un, 50Hz, 20℃);
Inter-Pole Withstand Voltage: 2.15Un for 5s, without permanent breakdown or flashover;
Pole-Shell Withstand Voltage: 2Un + 2kV (or 3kV if below 3kV) for 10s, without breakdown or flashover;
Power Factor Correction Capacitors are suitable for low-voltage power systems with a frequency of 50Hz or 60Hz. They are primarily used to improve power factor, reduce reactive power loss, enhance grid quality, and maximize transformer capacity, among other benefits.
Rated Voltage: 230V, 400V, 450V, 480V, 525V, 690V, 750V, 1200V, other custom voltages available;
Rated Capacity: 1kvar to 60kvar for 0.4~0.69kV, other custom capacities available;
Rated Frequency: 50Hz or 60Hz;
This series of controller is suitable for the automatic adjustment device of capacitor compensation device in low-voltage distribution system,with high-performance microprocessor as the core device,sampling physical quantity for power factor and reactive power in two optional modes,fundamental wave sampling against high harmonics of the grid,so that the power factor of the grid is stable in the range specified by the user,which can be widely applied to different grid conditions.
Rated working voltage (Ue):1140V
Rated working current (Ie):1600A
Rated frequency (fr):50A
Rated making capacity:4Ie(AC-4)
Rated working voltage (Ue):1140V
Rated working current (Ie):800A, 1000,A1250A
Rated frequency (fr):50A
Rated working voltage (Ue):1140V
Rated working current (Ie):630A
Rated thermal current(Ith):50Hz
Rated working voltage (Ue):1140V
Rated working current (Ie):400A
Rated thermal current(Ith):50Hz
Rated working voltage (Ue):1140V
Rated working current (Ie):250A
Rated frequency (fr):50Hz
Rated working voltage (Ue):1140V
Rated working current (Ie):80A,125A,160A
Rated frequency (fr):50Hz
Rated working voltage (Ue):1000V
Rated working current (Ie):800A、1000A、1250A、1400A
Rated thermal current(Ith):800A、1000A、1250A、1400A
Rated frequency (fr):50Hz
Rated working voltage (Ue):40.5KV
Rated working current (Ie):250A,400A, 630A
Rated frequency (fr):50Hz
Rated working voltage (Ue):40.5KV
Rated working current (Ie):630A/1250A
Rated frequency (fr):50Hz
Rated working voltage (Ue):7.2kV/12kV
Rated working current (Ie):400A,630A
Rated frequency (fr):50Hz
Power Factor Correction Capacitors
Optimize Energy, Enhance Efficiency, Create a Green Future
To meet the electrical energy demands of modern industries and businesses, we proudly introduce Power Factor Correction Capacitors that adhere to the International Electrotechnical Commission (IEC) standard 60831.
1.Rated Voltage Level (kV): 0.23, 0.25, 0.4, 0.45, 0.48, 0.525;
2.Rated Capacity (kvar): 1~50;
1~10kvar: Single-ended terminal;
12.5~30kvar: Screw terminal;
35~50kvar: Delta terminal(<400V);Screw terminal(>400V)
The active filter detects the load current in real time through the external current transformer CT, and calculates it through the internal DSP to extract the harmonic components of the load current, and then sends it to the internal IGBT through the PWM signal to control the inverter to generate a harmonic with the load.
The static var generator (ZYSVG) detects the load current in real time through an external current transformer (CT), analyzes the reactive power content of the load current through internal DSP calculations, and then controls the PWM signal generator to send a control signal according to the set value.